The purpose of this study was to develop a more powerful blood analysis method based on polarized surface enhanced Raman spectroscopy (SERS) technology for non-invasive and sensitive colorectal cancer (CRC) detection. The efficiency of different polarized scattering signals (non-polarization, parallel polarization and perpendicular polarization) on blood serum SERS was explored for the first time. Results demonstrated that polarized SERS was more sensitive to explore distinctive spectral differences between cancer and normal groups. And higher diagnostic accuracy of 91.6% could be achieved using polarized SERS integrated with PCA-LDA for classification of the two serum groups in comparison to conventional SERS technology. This exploratory study demonstrated that the nanobiosensor based on polarized SERS technique in conjunction with PCA-LDA provided a novel strategy for blood SERS analysis, and had the potential as a clinical complement for CRC screening.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: