Key result
The combination of intracardiac echocardiography and contact force sensing during catheter ablation of left ventricular papillary muscle arrhythmias resulted in lower VA recurrence (14.2% vs 50%; p=0.04).
Why the study?
Catheter ablation of ventricular arrhythmias arising from left ventricular papillary muscles is challenging, and whether combining ICE with contact force sensing improves acute and long-term outcomes remained unaddressed.
Does the combination of intracardiac echocardiography and contact force sensing improve acute and long-term outcomes in patients undergoing catheter ablation for left ventricular papillary muscle arrhythmias?
Observational (n=33)
Does the combination of intracardiac echocardiography and contact force sensing improve acute and long-term outcomes in patients undergoing catheter ablation for left ventricular papillary muscle arrhythmias?
Absolute Event Rate: 14.2% vs 50%
p-value: p=0.04
The combination of intracardiac echocardiography and contact force sensing during catheter ablation for left ventricular papillary muscle arrhythmias significantly improves acute success and reduces long-term arrhythmia recurrence.
Objectives: The catheter ablation of ventricular arrhythmias (VAs) arising from the left ventricular (LV) papillary muscles (PMs) is challenging. This study sought to address whether the combination of intracardiac echocardiography (ICE) and contact force sensing (CFS) can improve the acute and long-term ablation outcomes of left ventricular papillary muscle arrhythmias. Methods and Results: From May 2015 to August 2022, a total of thirty-three patients underwent catheter ablation for LV PM arrhythmias: VAs were located in anterolateral PMs in 11 and posteromedial PMs in 22. A combination of intracardiac echocardiography (ICE) and contact force sensing (CFS) was used in 21 of the 33 procedures. A mean of 6.93 ± 4.91 for lesions was used per patient, comparable between the CFS/ICE and no ICE/CFS (4.90 ± 2.23 vs. 10.17 ± 5.89; p = 0.011). The mean CF achieved in the ICE/CFS group was 7.52 ± 3.31 g. Less X-ray time was used in the combination group (CFS/ICE: 165.67 ± 47.80 S vs. no ICE/CFS: 365.00 ± 183.73 S; p < 0.001). An acute success rate of 100% was achieved for the ICE/CFS group (n = 22) and 66.67% for the no ICE/CFS group (n = 8). VA recurrence at the 11.21 ± 7.21-month follow-up was 14.2% for the ICE/CFS group and 50% for the no ICE/CFS group (p = 0.04). No severe complications occurred in all patients. Conclusions: The combination of intracardiac echocardiography (ICE) and contact force sensing (CFS) could provide precise geometries of cardiac endocavitary structures and accurate contact information for the catheter during ablation, which improved acute and long-term ablation outcomes. The routine adoption of this strategy should be considered to improve the outcomes of LV PM VA ablation.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2023) conducted an observational in Left ventricular papillary muscle arrhythmias (n=33). Combination of intracardiac echocardiography (ICE) and contact force sensing (CFS) vs. No ICE/CFS was evaluated on Ventricular arrhythmia (VA) recurrence (p=0.04). The combination of intracardiac echocardiography and contact force sensing during catheter ablation of left ventricular papillary muscle arrhythmias resulted in lower VA recurrence (14.2% vs 50%; p=0.04).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: