Mechanical property of GdBa2Cu3Oy(GdBCO) coated conductor was investigated at 4.2 K in a magnetic field by two ways, which are the tensile test and the hoop stress test. The tensile stress/strain dependence of critical current (Ic) of a 2 mm width conductor was explored at 4.2 K, 18 T. The result provided thatIc-reversible strain limit existed in between 0.43% and 0.46%, corresponding to 907 MPa and 960 MPa in stress, and the elastic constant was 203 GPa. The hoop stress test has been performed at 4.2 K, 11 T. A test coil was fabricated by winding a 5 mm width conductor on a 270 mm diameter GFRP bobbin by 1.5 turns. The maximum value of applied hoop stress, which was deduced from a product of magnetic field, current density and coil radius, was 1322 MPa. Five strain gauges glued on the conductor surface showed almost the same values, which were in a range of 0.64% to 0.67%, indicating the uniform longitudinal deformation. Furthermore, the hoop stress-strain characteristics were linear, suggesting an elastic deformation. The deduced elastic constants were in a range of 196-204 GPa. It was confirmed that the GdBCO coated conductor performance was deteriorated irreversibly by 1322 MPa hoop stress, whereas not by 1302 MPa hoop stress.
No takes yet. Share an insight, caveat, or question.
Nishijima et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: