A small-sized, high momentum rate (>10 −2 N), dynamically actuated microvalve fulfilling the functional specifications for active aerodynamic flow control was designed, fabricated and characterized. The prototype consists of a microfabricated silicon channel pinched by an actuated poly(dimethyl siloxane) (PDMS) polymer membrane. Actuation is provided by coupling an inductive driving coil and a NdFeB permanent magnet fixed on the PDMS elastomeric membrane. The development of a specific microfabrication process, and a complete characterization of the fabricated prototypes are presented in this paper. The yield air microjet performances reach 150 m s −1 for an actuation frequency situated in the range [0 Hz–400 Hz] and an outlet area of about 1 . Experimental results also show that the use of a vectoring plate placed at the outlet of the microvalve provided not only easier integration of the microsystem, but also improved the penetration of the microjet into the main flow.