Electrical conductivity (EC) is used for monitoring different types of aqueous systems. The measured EC value at any temperature needs to be corrected for a standard temperature, for reporting or comparison, since EC is dependent on temperature. A temperature compensation factor has been derived for conductivity correction from anaerobic digester supernatant/centrate samples of five different wastewater treatment plants in western Canada. For a temperature compensation factor of 0.0198°C−1, corresponding to the standard temperature at 25°C, the estimated EC25 values were found to be reasonably accurate, with a maximum error of 2.01%. The estimated EC values, based on any standard temperature, were found to be statistically similar to each other. Considering the temperature dependence of EC, a relationship between EC and ionic strength was developed in this study for anaerobic digester supernatant/centrate samples. This relationship can be used to estimate the ionic strength of the solution in a system associated with struvite formation from anaerobic digester supernatant/centrate and effectively monitor the system performance.