A method for enhancing torque capability of a dual three-phase permanent magnet synchronous machine (PMSM) based on conventional dual three-phase drive system by injecting the fifth and seventh current harmonics without any hardware re-configuration is proposed in this paper. Compared with the third current harmonic injection, which is commonly used to enhance the torque capability of dual three-phase machine, the two isolated neutral points of each set of single three-phase windings do not need to be reconnected to the middle point of dc-link capacitors or an additional power switching bridge to provide flowing path for zero-sequence current. Further, no additional current sensors are required to obtain the feedback of zero-sequence current to regulate it effectively. For a prototype dual three-phase PMSM, the average torque increases approximately by 9% at the cost of 0.56% increase in the 12th harmonic torque ripple. The effectiveness of the torque capability enhancement is confirmed by experiments.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: