This paper describes a phenomenon caused by EDMed sludge. When the electrode comes in touch with the workpiece through EDMed sludge, current flows through the sludge and the bridge of sludge is made. When this bridge is made, it brings about the concentration of discharge pulses and damages the machined surface.
No takes yet. Share an insight, caveat, or question.
A 1998 study studied this question.