Phenol red was immobilised into a polysiloxane matrix using a sol-gel process to form pH optical sensors. The sol-gel was obtained by hydrolysis of tetraethoxysilane (TEOS) in the presence of phenol red (PR) and the appropriate surfactant. Different surfactants, namely cetyltrimethylammonium bromide (CTAB), dodecyldimetyl amino-oxide (GLA) and Triton X-100 (TX-100), were employed. Interestingly, the use of surfactants significantly improved the mesostructure of the silica and increased the porosity of the system. The two response pH ranges were shifted to pH 0.0–3.0 and pH 10.5–1.5M [OH−] compared with those of the free PR (pH 0.0–3.0 and pH 6.5–9.5). It is found that the pH response and the pKa shift of the phenol red were dependent, not only on the silica matrix but also on the ionic properties of surfactants. In the case of ionic surfactants such as CTAB or GLA, there was further shift to more acidic and more basic pH, whereas in the case of non-ionic surfactants such as TX-100 no significant change of the pH curve was observed.