Key result
A novel method for conformity assessment testing of ECG devices during post-market surveillance significantly improved device accuracy and reliability across healthcare institutions.
Why the study?
Standardised conformity assessment testing methods for post-market surveillance of electrocardiography devices under new Medical Device Regulation are lacking.
A standardized conformity assessment testing method for ECG devices during post-market surveillance may improve device accuracy and reliability.
May support standardized ECG device surveillance; leaves open need for prospective validation before clinical adoption.
BACKGROUND: Monitoring cardiac parameters is the fundamental aspect of every diagnostic process and is facilitated by electrocardiography (ECG) devices. This way, continuous state-of-the-art performance of ECG devices can be ensured. The new Medical Device Regulation (MDR) defines medical device post-market surveillance (PMS) as performed by independent, third-party, notified bodies more strategically in hope to improve traceability of device performance. However, there is still an apparent gap in terms of standardised conformity assessment testing methods. OBJECTIVE: This paper proposes a novel method for conformity assessment testing of ECG devices for post-market surveillance purposes. METHOD: The method was developed on the basis of International Organisation of Legal Metrology (OIML) guidelines and applied in healthcare institutions from 2018 to 2021. RESULTS: The developed method was validated in healthcare institutions of all levels. The results obtained during validation suggest that conformity assessment testing of the ECG device as a method used during PMS contributes to significant improvement in devices' accuracy and reliability. CONCLUSION: A standardized approach in conformity assessment testing of ECG devices during PMS, besides increasing reliability of the devices, is the first step in the digital transformation of the management of these devices in healthcare institutions opening possibility for use of artificial intelligence.
No takes yet. Share an insight, caveat, or question.
Badnjević et al. (2022) studied Electrocardiography (ECG) device performance. Novel method for conformity assessment testing was evaluated on Device accuracy and reliability. A novel method for conformity assessment testing of ECG devices during post-market surveillance significantly improved device accuracy and reliability across healthcare institutions.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: