Key result
Electrophysiological mapping following the Cox-Maze IV procedure significantly increased freedom from atrial fibrillation at 6 months compared to the standard procedure (88.1% vs. 13.2%).
Why the study?
To evaluate the safety and efficacy of electrophysiological mapping following the Cox-Maze IV procedure and assess whether AF recurrence correlates with completeness of bidirectional electrical isolation and post-procedure AF inducibility.
Does electrophysiological mapping following the Cox-Maze IV procedure improve relief from atrial fibrillation at 6 months in patients with valvular disease and persistent AF?
RCT (n=80)
Open-label
Randomly assigned
No
Does electrophysiological mapping following the Cox-Maze IV procedure improve relief from atrial fibrillation at 6 months in patients with valvular disease and persistent AF?
Electrophysiological mapping following the Cox-Maze IV procedure safely and effectively guides supplementary ablation of non-transmural lesions, leading to significantly higher freedom from atrial fibrillation at 6 months.
Intraoperative mapping may identify incomplete lesions to guide ablation and predict 6-month AF recurrence; leaves open whether routine use improves outcomes in valve patients.
Objective: The objective of this study was to observe the safety and efficacy of electrophysiological mapping following the Cox-Maze IV procedure and to investigate whether a correlation exists between recurrence of atrial fibrillation (AF) with the completeness of bidirectional electrical isolation and the inducibility of AF immediately after the Cox-Maze IV procedure. Methods: Totally, 80 consecutive patients who suffered from aortic valve or mitral valve disease and persistent AF were randomly enrolled into the control group and electrophysiological mapping following the Cox-Maze IV group (Electrophysio-Maze group). In the Electrophysio-Maze group, patients underwent concomitant Cox-Maze procedure and following electrophysiological mapping of ablation lines in mitral isthmus, left atrial "box," and tricuspid annulus. If the bidirectional electrical isolation of tricuspid annulus ablation line is incomplete, whether to implement supplementary ablation will be independently decided by the operator. Before and after the Cox-Maze IV procedure, AF induction was performed. All patients in both groups were continuously followed-up and underwent electrocardiogram Holter monitoring after 6 months. Results: In total, 42 Electrophysio-Maze patients and 38 controls were enrolled. Compared with patients in the control group, there were shorter hospital stay, better cardiac remodeling changes, and higher relief from AF during the follow-up period of 6 months in the Electrophysio-Maze group. Within the Electrophysio-Maze group, the rate of incomplete the bidirectional electrical isolation of "box" ablation lines was zero, and the rate of incomplete bidirectional electrical isolation of mitral isthmus ablation line or tricuspid annulus ablation line was 23.8%. After two cases of successful complementary ablation on the tricuspid annulus ablation line, the final incomplete bidirectional electrical isolation of annulus ablation lines was 19.0%. There were correlations between late AF recurrence after 6 months with incomplete bidirectional electrical isolation of annulus ablation lines and AF induction immediately after the Cox-Maze IV procedure. Conclusion: Electrophysiological mapping following the Cox-Maze procedure is safe and effective. Electrophysiological mapping in the Cox-Maze procedure can find out the non-transmural annulus ablation lines by assessing the completeness of bidirectional electrical isolation of ablation lines, guide supplementary ablation, and predict AF recurrence after 6 months.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2022) conducted an RCT in Persistent atrial fibrillation and valvular heart disease (n=80). Electrophysiological mapping following the Cox-Maze IV procedure vs. Standard Cox-Maze IV procedure was evaluated on Freedom from atrial fibrillation at 6 months (p=<0.001). Electrophysiological mapping following the Cox-Maze IV procedure significantly increased freedom from atrial fibrillation at 6 months compared to the standard procedure (88.1% vs. 13.2%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More from Frontiers in Cardiovascular Medicine