Key result
Phase related external suction (PRES) successfully manipulated baroreceptor firing across two experiments by applying short changes in cuff pressure tied to different phases of the cardiac cycle.
Why the study?
Does phase related external suction (PRES) tied to the cardiac cycle reduce heart rate in healthy volunteers?
Does phase related external suction (PRES) tied to the cardiac cycle reduce heart rate in healthy volunteers?
Phase related external suction (PRES) is a valid noninvasive method for stimulating carotid baroreceptors in humans that allows for an effective psychological control condition.
Validates PRES for noninvasive baroreceptor stimulation with control condition; extends autonomic research tools but leaves clinical heart rate effects open.
To study physiological and psychological effects of baroreceptor activity, the cervical neck cuff technique has been frequently used to stimulate the carotid baroreceptors mechanically. Using this technique, no satisfying control conditions to date have been available. Because the carotid stretch receptors are sensitive not only to the pressure level, but also to the rate of change, it is possible to manipulate the receptor firing through changes in carotid pulse amplitude. The device described here relies on the application of short changes in cuff pressure tied to different phases within the cardiac cycle (phase related external suction (PRES)). A brief external suction during systole has potent stimulatory effects on baroreceptors whereas the application of the very same pressure pulse during diastole inhibits the firing burst associated with the pulse wave. To allow an ongoing period of stimulation, a sequence of alternating negative/positive pressure pulses is applied. In the stimulation condition, the R-wave of the electrocardiogram triggers a negative pulse which is followed by a positive one during diastole. In the control condition this relationship is reversed. Two experiments are reported confirming different baroreceptor effects of the two conditions. PRES allows for blind or double-blind experiments to investigate effects of baroreceptor activity on physiology and behavior.
No takes yet. Share an insight, caveat, or question.
Rau et al. (1992) studied this question. Phase related external suction (PRES) vs. Reversed relationship of pressure pulses (control condition) was evaluated on Baroreceptor effects. Phase related external suction (PRES) successfully manipulated baroreceptor firing across two experiments by applying short changes in cuff pressure tied to different phases of the cardiac cycle.