Magnetization losses of Rutherford MgB 2 cables of different sheath materials (Cu, CuNi and Al + Al 2 O 3 ) made by powder-in-tube and internal magnesium diffusion processes were studied experimentally. Short cable samples consisting of 12 strands were measured in the temperature range from 18 K up to 40 K, external fields up to 70 mT and frequencies 72 Hz and 144 Hz. The effects of inter-strand resistance by soldering and external field orientation (perpendicular and parallel) were also tested. The impact of eddy current losses in the sheath material was determined by the loss measurement in cable samples without MgB 2 . It was found that very high eddy current losses of Cu sheathed strands overlap the hysteresis loss. The lowest AC losses at 20 K were measured for a Rutherford MgB 2 cable with an Al + Al 2 O 3 sheath, which makes it attractive for applications where low loss and also low coil mass are required (e.g. wind turbines or airborne engines).