Bi-2212 offers a lot of opportunities for very high fields at low temperature. The current density is large under high fields, particularly with recent enhanced results. The Bi-2212 conductor may be a round strand: a very favorable shape to wind and to make high-current Rutherford cables required for protection. There is no satisfying high-current cable with YBCO. One drawback of Bi-2212 is their low mechanical properties. Large fields and current densities indeed induce high mechanical stresses. To improve the mechanical properties of Bi-2212 strands, Nexans has proposed to reinforce it with a metal sheath wrapped around using their process of shaping and welding. The sheath is wrapped around the strand and laser welded, and the whole is drawn to a diameter of 0.9 mm. Several materials for the sheath were studied to determine their resistance to thermal treatment of Bi-2212 and their mechanical properties after treatment. We choose Inconel 601. A method of perforating the sheath has been developed to enable the oxygenation during the heat treatment. A 6 + 1 conductor has also been produced around an Inconel core and inserted in a tube. The 6 + 1 reinforced conductor was then drawn to a diameter of 2.7 mm. The Icmeasurements at 4 K show that our mechanical reinforcement does not significantly lower the transport capacities. They therefore validate the method and the heat treatment.
No takes yet. Share an insight, caveat, or question.
Tixador et al. (2014) studied this question.