Frequency-stabilized cavity ring-down spectroscopy was used to study CO2 lineshapes in the (20013) ← (00001) band centered near 2.06 μm. Two rovibrational transitions were chosen for this study to measure non-Voigt collisional effects for air-broadened lines over the pressure range of 7 kPa-28 kPa. Lineshape analysis for both lines revealed evidence of simultaneous Dicke (collisional) narrowing and speed-dependent effects that would introduce biases exceeding 2% in the retrieved air-broadening parameters if not incorporated in the modeling of CO2 lineshapes. Additionally, correlations between velocity- and phase/state changing collisions greatly reduced the observed Dicke narrowing effect. As a result, it was concluded that the most appropriate line profile for modeling CO2 lineshapes near 2.06 μm was the correlated speed-dependent Nelkin-Ghatak profile, which includes all of the physical effects mentioned above and leads to a consistent set of line shape parameters that are linear with gas pressure.
No takes yet. Share an insight, caveat, or question.
Bui et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: