Key result
A proposed method generalizing inter-unit reliability estimations to standardized measures helps determine the minimum number of facilities needed for quality measure testing in dialysis.
Why the study?
Methods were needed to determine the minimum number of dialysis facilities to recruit for quality measure testing to ensure desirable precision based on inter-unit reliability.
Accurate estimation of inter-unit reliability for dialysis facility quality measures requires recruiting at least 75 facilities to achieve a confidence interval width of less than 0.2.
Urges larger samples for reliable dialysis quality metrics; leaves open prospective validation of the proposed method.
Facility-specific quality measures are commonly used to monitor dialysis facilities. To successfully develop, test and validate quality measures, a subset of facilities are often recruited for preliminary evaluations. To ensure that the facility-specific measures will achieve a desirable precision, it is often of interest to determine a minimum number of facilities that should be recruited. To achieve this, we propose a method based on the inter-unit reliability (IUR), which is commonly used to assess quality measures. Accurate estimates of the IUR are important to ensure that the quality measure will achieve a desirable precision. We first review existing methods of estimating the IUR for quality measures that are based on sample averages. We then generalize the IUR estimations to more complicated standardized measures. In particular, the confidence intervals of the IUR are calculated, with the width of this confidence interval measuring the precision of the estimate of the IUR. To assess the performance of the estimated IUR with various numbers of facilities, a simulation study is conducted. The IURs are then computed to develop and implement a quality measure that is used to guard against high ultrafiltration rates for adult dialysis patient with End-Stage Renal Disease. The estimated values are helpful to determine a minimum number of facilities that should be recruited in the measure testing process.
No takes yet. Share an insight, caveat, or question.
He et al. (2019) studied End-Stage Renal Disease. Inter-unit reliability (IUR) estimation method vs. Existing methods based on sample averages was evaluated on Precision of the estimate of the IUR (confidence interval width). A proposed method generalizing inter-unit reliability estimations to standardized measures helps determine the minimum number of facilities needed for quality measure testing in dialysis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: