Key result
The femoral approach for coronary sinus cannulation achieved a 99.3% procedural success rate in patients undergoing electrophysiological studies and ablation.
Why the study?
Does the femoral approach for coronary sinus cannulation provide high procedural success and safety in patients undergoing EPS and ablation?
Cohort (n=1,320)
No
Does the femoral approach for coronary sinus cannulation provide high procedural success and safety in patients undergoing EPS and ablation?
The femoral approach for coronary sinus cannulation during EPS and ablation is safe and highly successful (99.3%), challenging previous reports of lower success rates compared to the subclavian approach.
May support femoral CS cannulation in EPS/ablation; leaves open superiority over subclavian in randomized trials.
BACKGROUND: It has been reported that the cannulation of coronary sinus (CS) from the femoral approach is safer than the traditional subclavian approach but is associated with a lower rate of success. We aimed to test the validity of this claim. METHOD: We evaluated retrospectively 1320 consecutive patients who underwent electrophysiological study (EPS) or ablation over a period of three years using a prospectively collected data. In cases requiring CS cannulation, it was attempted first from the femoral approach, switching if necessary to a subclavian approach when the femoral route failed. RESULTS: Out of 1320 patients, 1165 (88.3%) required CS cannulation. The CS was successfully cannulated from the femoral approach in 99.3% of the cases in which it was attempted. One patient (0.09%) developed transient first degree atrioventricular block during an ablation procedure for AV nodal re-entrant tachycardia during cannulation of the CS that resolved within 3 min. Femoral access failed in 8 patients. In 4 of these cases, the procedure was concluded using CS cannulation via subclavian or jugular venous access. In the other 4 cases, the procedure was concluded successfully without CS cannulation, including an AF ablation in which CS cannulation proved impossible by either subclavian or femoral approach. CONCLUSION: Femoral access can be used for CS cannulation with a high rate of procedural success in the vast majority of patients undergoing EPS and ablation. This approach is safe, and associated with a high rate of procedural success.
No takes yet. Share an insight, caveat, or question.
Atty et al. (2011) conducted a cohort in Electrophysiological study (EPS) or ablation (n=1,320). Femoral approach to coronary sinus catheterisation vs. Subclavian approach was evaluated on Successful cannulation of the coronary sinus. The femoral approach for coronary sinus cannulation achieved a 99.3% procedural success rate in patients undergoing electrophysiological studies and ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: