In this study, a rapid competitive immunochromatographic test strip has been developed for specifically testing residues of difloxacin (DIF). 1H10-2B2, one of the three hybridoma lines that were tested and selected by enzyme linked immunosorbent assay, was used in the test strip. The monoclonal antibody has a good sensitivity with an IC50 of 2.2 ng/mL to DIF, 0.24% cross-reactivity towards danofloxacin and no cross-reactivity towards other related compounds and other drugs. The calibration curve of DIF test strip presented a typical sigmoidal curve. In practice, the lower limit of detection using a strip reader was 0.5 ng/ml while 2 ng/ml by unaided visual assessment. Samples of milk were spiked at 2–8 ng/mL, presenting recoveries between 94.5 and 107%, and the coefficient of variation (CV,%) (1.6–9%). The data above suggests that the strip meets the requirements of high sensitivity, good specificity, simplicity and speed, as well as the characteristics of reproducibility and accuracy.
No takes yet. Share an insight, caveat, or question.
Li et al. (2010) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: