In osteosynthesis of proximal humerus fractures, the screws frequently penetrate the joint. Using orthogonal frontal and lateral radiographs, we found unrecognized pin penetration in 8 of 30 patients during fixation of unstable neck fractures of the humerus.
No takes yet. Share an insight, caveat, or question.
Hernigou et al. (2002) studied this question.