Impinging stream contactors provide a novel configuration for drying and/or chemical reactions of particulates, pastes or suspensions which can be dispersed in a flowing gas stream. Essentially they consist of one or more highly turbulent “impingement” zones formed by collision of two opposing jets (OJ) in a confied channel or duct. The objective of this paper is to present computational fluid dynamic predictions for two-dimensional turbulent opposing jets over a range of nozzle-to-nozzle separations and jet Reynolds numbers for the simulation of single particle drying in these systems using superheated steam. A number of different turbulence models were tested ( e.g. high Reynolds, Lam-Bremhorst, Launder and Sharma models etc.). Predictions are performed in two distinct parts. In the first part a power law, finite volume method based on the “SIMPLEC” algorithm is used to solve the momentum and energy conservation equations for air in OJ systems in order to gain insight into their
No takes yet. Share an insight, caveat, or question.
Hosseinalipour et al. (1995) studied this question.