The ac-dc differences of a reference group of thermoelements have been evaluated at audio frequencies to a few parts per million (ppm) at currents from 5 to 20 mA. A technique for comparing the ac-dc differences of two thermoelements with an uncertainty of about 2 ppm has been developed. Two 5 mA thermoelements are used with a plug-in set of resistors of computable reactances to form thermal voltage converters for voltage measurements. With this same technique adjacent ranges of these converters can be compared to step up from 0.5 to 500 V to better than 10 ppm.
No takes yet. Share an insight, caveat, or question.
Hermach et al. (1966) studied this question.