Numerical simulation reveals position- and shape-dependent terahertz resonance shifts for microplastics in water, highlighting design targets for integrated microfluidic sensors.
Conventional vibrational spectroscopy provides chemically specific identification of microplastics but often requires extensive sample preparation and particle-by-particle analysis. This study numerically examines a terahertz split-ring resonator (SRR) metasurface as a transducer for local dielectric perturbations in water. A finite-element model was used to quantify the spatial response of the active gap. A 5 × 5 sensitivity map yielded frequency shifts of 0.37–0.97 GHz for equivalent local polystyrene perturbations, with maxima at the gap corners, consistent with simulated field localization. An equal-volume shape study compared a spherical inclusion (Δf = 4.34 GHz) with ellipsoids of identical volume and constant height; shifts of 4.25–4.56 GHz demonstrated dependence on in-plane orientation. At the highest-sensitivity cell, shifts of 1.12, 0.97, 0.69, 0.25, and 0.24 GHz were obtained for PE, PS, PET, and two synthetic high-permittivity references, respectively. For three four-corner configurations, the observed shifts agreed with reference-cell estimates within 1.4%. The results identify positional, dielectric, and geometric factors that should be controlled in future microfluidic preconcentration and hybrid-sensing experiments.
No takes yet. Share an insight, caveat, or question.
Ruszczynski et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: