Sorption and desorption isotherms of four gelatin powder from different sources (Bovine B-225, Pig skin A-270, Fish FG-260 and Poultry PG-240) were determined at 25°C by using the DVS machine at wide relative humidity range (0% to 90%). Data were fitted with the GAB and Peleg models. The isotherms showed the characteristic shape type II according to Brunauer classification. Both GAB and Peleg models fitted very well (R 2 = 0.999) to experimental data. Peleg model fitted much better at the desorption process. Monolayer values (mo ) for GAB model resulted around 6% for sorption and 9% for desorption. FG-260 showed the higher hysteresis (10%) giving evidence of high difficulty in removing water from the porous capillary during desorption. B-225 resulted in much better storage stability with the lowest mo at the sorption stage (5.95%), and the best ability to remove water from the matrix during desorption (mo = 9.30%).
No takes yet. Share an insight, caveat, or question.
Aguirre‐Álvarez et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: