Key result
The 8 F Angio-Seal percutaneous closure device successfully and safely closed an inadvertent subclavian artery cannulation during pacemaker implantation, with no obstruction or hemorrhage at 6 months.
Case Report (n=1)
No
The Angio-Seal percutaneous closure device can be a rapid, effective, and safe option for managing inadvertent subclavian artery cannulation during pacemaker implantation.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2017) conducted a case report in Inadvertent subclavian artery cannulation during pacemaker implantation (n=1). 8 F Angio-Seal percutaneous closure device was evaluated on Successful closure of subclavian artery cannulation without hemorrhage or obstruction. The 8 F Angio-Seal percutaneous closure device successfully and safely closed an inadvertent subclavian artery cannulation during pacemaker implantation, with no obstruction or hemorrhage at 6 months.