Key result
The modified 'Double Wire' Angio-Seal technique successfully achieved hemostasis in 100% of 21 patients following percutaneous balloon aortic valvuloplasty.
Why the study?
Does the modified 'double wire' Angio-Seal closure technique safely achieve hemostasis in patients undergoing percutaneous balloon aortic valvuloplasty?
Observational (n=21)
Does the modified 'double wire' Angio-Seal closure technique safely achieve hemostasis in patients undergoing percutaneous balloon aortic valvuloplasty?
The modified 'double wire' Angio-Seal technique is a feasible and effective method for achieving hemostasis after large-bore femoral access in balloon aortic valvuloplasty.
Supports feasibility after large-bore access in balloon aortic valvuloplasty; hypothesis-generating and requires prospective validation before practice change.
OBJECTIVES: To report the feasibility of a collagen-mediated closure device using a modified Angio-Seal closure technique for access site management following percutaneous balloon aortic valvuloplasty (BAV). BACKGROUND: With the advent of percutaneous aortic valve replacement therapies, there has been a resurgence of interest in BAV procedures. Vascular complications, including bleeding, are a common source of morbidity post procedure as a result of the requirement for large bore femoral artery access. The use of vascular closure devices may reduce bleeding complications. METHODS: We describe a new technique for vascular closure in this setting. At the conclusion of the valvuloplasty procedure, two 0.035'' wires are inserted through the femoral artery sheath. A conventional collagen-mediated closure device (8F Angio-Seal) is deployed over the first wire and along side the second wire. If immediate hemostasis is not achieved, a second device is loaded onto the second wire and deployed to achieve hemostasis. RESULTS: Percutaneous BAV was performed in 21 patients. Hemostasis was successfully achieved in all patients with either a single 8F Angio-Seal closure device (18 patients) or after placement of a second device (three patients). CONCLUSIONS: The modified "Double Wire" Angio-Seal technique is a feasible method for hemostasis following percutaneous BAV.
No takes yet. Share an insight, caveat, or question.
Bui et al. (2009) conducted an observational in Patients undergoing percutaneous balloon aortic valvuloplasty (BAV) (n=21). Modified 'Double Wire' Angio-Seal closure technique was evaluated on Hemostasis. The modified 'Double Wire' Angio-Seal technique successfully achieved hemostasis in 100% of 21 patients following percutaneous balloon aortic valvuloplasty.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: