Key result
Explainable machine learning models revealed that the field emitted current following an initial breakdown is closely related to the probability of another breakdown occurring shortly thereafter.
Why the study?
Vacuum arcs or radio frequency breakdowns limit high-gradient performance of normal conducting rf cavities, prompting a search for unrecognized features related to their incidence.
Machine learning models identified that field emitted current following an initial breakdown predicts subsequent breakdowns in high-gradient rf cavities.
May flag imminent re-breakdown via post-event emission; leaves open prospective validation before operational integration.
The occurrence of vacuum arcs or radio frequency (rf) breakdowns is one of the most prevalent factors limiting the high-gradient performance of normal conducting rf cavities in particle accelerators. In this paper, we search for the existence of previously unrecognized features related to the incidence of rf breakdowns by applying a machine learning strategy to high-gradient cavity data from CERN's test stand for the Compact Linear Collider (CLIC). By interpreting the parameters of the learned models with explainable artificial intelligence (AI), we reverse-engineer physical properties for deriving fast, reliable, and simple rule--based models. Based on 6 months of historical data and dedicated experiments, our models show fractions of data with a high influence on the occurrence of breakdowns. Specifically, it is shown that the field emitted current following an initial breakdown is closely related to the probability of another breakdown occurring shortly thereafter. Results also indicate that the cavity pressure should be monitored with increased temporal resolution in future experiments, to further explore the vacuum activity associated with breakdowns.
No takes yet. Share an insight, caveat, or question.
Obermair et al. (2022) studied Radio frequency (rf) breakdowns in particle accelerators. Explainable machine learning strategy was evaluated on Occurrence of rf breakdowns. Explainable machine learning models revealed that the field emitted current following an initial breakdown is closely related to the probability of another breakdown occurring shortly thereafter.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: