We installed a Harvard particle concentrator with PM2.5 size-selective inlet and two virtual impactor stages, in a movable human exposure laboratory located in metropolitan Los Angeles, where ambient PM2.5 is unusually high. The exposure chamber, a modified body Plethysmograph of ~2000 L volume, operated at flow near 200 L/min and pressure near 25 cm H2O below atmospheric. The concentrator usually delivered seven to nine times the ambient concentration of PM2.5. When necessary, part of its output was diverted through a HEPA filter to control the exposure concentration. Occasionally the concentration factor decreased due to rapid fouling of impactor slits under humid and/or highly polluted ambient conditions. Initial tests with an investigator (healthy male, age 53 yr) at rest in the chamber showed no untoward effects except rare transient mild substernal irritation, brief mild middle ear discomfort from pressure changes upon starting or stopping the concentrator, and occasional ectopic heartbeats (which a...