Key result
Granisetron transdermal system was not associated with clinically significant effects on QTcF, with day 3 placebo-corrected changes from baseline varying between 0.2 and 1.9 ms.
Why the study?
Does granisetron (intravenous or transdermal) prolong the QTcF interval compared to placebo in healthy subjects?
RCT (n=240)
parallel four-arm
Does granisetron (intravenous or transdermal) prolong the QTcF interval compared to placebo in healthy subjects?
Granisetron administered via transdermal system or intravenously does not cause clinically significant QT prolongation in healthy subjects.
Supports QTc-safe use of granisetron transdermal system without routine monitoring; extends randomized IV safety data to transdermal delivery in oncology.
PURPOSE: The need for greater clarity about the effects of 5-HT(3) receptor antagonists on cardiac repolarization is apparent in the changing product labeling across this therapeutic class. This study assessed the repolarization effects of granisetron, a 5-HT(3) receptor antagonist antiemetic, administered intravenously and by a granisetron transdermal system (GTDS). EXPERIMENTAL DESIGN: In a parallel four-arm study, healthy subjects were randomized to receive intravenous granisetron, GTDS, placebo, or oral moxifloxacin (active control). The primary endpoint was difference in change from baseline in mean Fridericia-corrected QT interval (QTcF) between GTDS and placebo (ddQTcF) on days 3 and 5. RESULTS: A total of 240 subjects were enrolled, 60 in each group. Adequate sensitivity for detection of QTc change was shown by a 5.75 ms lower bound of the 90% confidence interval (CI) for moxifloxacin versus placebo at 2 hours postdose on day 3. Day 3 ddQTcF values varied between 0.2 and 1.9 ms for GTDS (maximum upper bound of 90% CI, 6.88 ms), between -1.2 and 1.6 ms for i.v. granisetron (maximum upper bound of 90% CI, 5.86 ms), and between -3.4 and 4.7 ms for moxifloxacin (maximum upper bound of 90% CI, 13.45 ms). Day 5 findings were similar. Pharmacokinetic-ddQTcF modeling showed a minimally positive slope of 0.157 ms/(ng/mL), but a very low correlation (r = 0.090). CONCLUSION: GTDS was not associated with statistically or clinically significant effects on QTcF or other electrocardiographic variables. This study provides useful clarification on the effect of granisetron delivered by GTDS on cardiac repolarization.
No takes yet. Share an insight, caveat, or question.
Mason et al. (2012) conducted an RCT in healthy subjects (n=240). Granisetron transdermal system (GTDS) and intravenous granisetron vs. Placebo or oral moxifloxacin was evaluated on difference in change from baseline in mean Fridericia-corrected QT interval (QTcF) between GTDS and placebo (ddQTcF) on days 3 and 5. Granisetron transdermal system was not associated with clinically significant effects on QTcF, with day 3 placebo-corrected changes from baseline varying between 0.2 and 1.9 ms.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: