Reflection of ion-acoustic waves from the ion sheath in front of the separation grid in a double-plasma device has been investigated experimentally. The plasma potential φ of the source plasma was controlled relative to that of the target plasma. When eφ < κΤe, where Τe is the electron temperature, no reflection was observed. The reason for this is that ions are drifting towards the grid with the Bohm velocity, i.e. the ion-acoustic velocity. When eφ > κΤe the reflected wave consists of the ion-acoustic wave and the ion beam mode. The reflection coefficient for the ion-acoustic wave is about unity. This high efficiency is due to reflection of the ions themselves.
No takes yet. Share an insight, caveat, or question.
Nakamura et al. (1989) studied this question.