OBJECTIVE: We evaluated the effect of particle size on MR contrast-enhancing properties of arabinogalactan-coated superparamagnetic iron oxide (AG-SPIO) in tumor-bearing rats. MATERIALS AND METHODS: T2*-weighted gradient-recalled echo MR studies were performed on rats with surgically implanted liver tumors before and after AG-SPIO administration. Contrast-to-noise ratio (CNR) and percent contrast enhancement (PCE) were calculated for animals given small (15.7 +/- 9.5 nm: n = 6), medium (49.1 +/- 19.7 nm; n = 4), and large (86.9 +/- 27.5 nm; n = 4) particles intravenously (10 mumol Fe/kg). RESULTS: Postcontrast CNRs were 15.8 +/- 6.9, 8.9 +/- 4.1, and 10.0 +/- 1.8 for small, medium, and large particle groups, respectively. The PCE was -60.0 +/- 3.3, -75.5 +/- 7.9, and -80.5 +/- 1.2%. There was a significant difference in preversus postcontrast CNR for all particle sizes (p < 0.001) and in PCE for small particles as compared with the two larger sizes (p < 0.001). There was no between-group statistical difference in postcontrast CNR for any particle size. CONCLUSION: Larger AG-SPIO particles slightly improve liver contrast enhancement, but have no significant effect on hepatic lesion detection as assessed by CNR.
No takes yet. Share an insight, caveat, or question.
Wisner et al. (1995) studied this question.