Key result
A noninvasive pulsatile device enhancing endothelial shear stress restored hemodynamics (systolic blood pressure >100 mmHg) and urine output in pediatric animal models of refractory cardiac arrest.
Why the study?
Critically ill COVID-19 patients often develop multiorgan failure or cardiac arrest aggravated by mechanical assist devices, prompting exploration of endothelial shear stress enhancement and pulmonary vascular resistance management in ARDS.
Does a noninvasive pulsatile circulatory flow restoration device improve hemodynamics and tissue oxygenation in pediatric animal models of sudden cardiac arrest?
Does a noninvasive pulsatile circulatory flow restoration device improve hemodynamics and tissue oxygenation in pediatric animal models of sudden cardiac arrest?
A novel noninvasive pulsatile device restored systemic hemodynamics and urine output in pediatric animal models of prolonged cardiac arrest, suggesting potential utility for endothelial shear stress enhancement in critical conditions like ARDS.
Should not change pediatric resuscitation practice; leaves open translation of pulsatile endothelial shear stress devices to human cardiac arrest.
Rationale: Most critically ill Covid-19 patients succumb to multiple organ failure and / or cardiac arrest as a result of comorbid endothelial dysfunction disorders which had probably aggravated by conventional mechanical assist devices. Even worse, mechanical ventilators prevent the respiratory pump from performing its crucial function as a potential generator of endothelial shear stress (ESS) which controls microcirculation and hemodynamics since birth. The purpose of this work is to bring our experience with ESS enhancement and pulmonary vascular resistance (PVR) management as a potential therapeutic solution in acute respiratory distress syndrome (ARDS). We propose a noninvasive device composed of thoracic and infradiaphragmatic compartments that will be pulsated in an alternating frequency (20/40 bpm) with low-pressure pneumatic generator (0.1-0.5 bar). Oxygen supply, nasogastric ± endotracheal tubes are considered. Proof-of-concept: prototypes were tested in pediatric models of refractory cardiac arrest (≥20min), showed restoration of hemodynamics (BP≥100 mm Hg) and urine output, regardless of heartbeats, pharmacological supports and mechanical ventilation. Conclusions ESS enhancement represents a more effective treatment to increase tissue oxygenation and improve hemodynamic in ARDS. A cost-effective method which could be induced with a non-invasive pulsatile device adaptable to cardiopulmonary-circulatory biophysics to maintain a fully functional respiratory pump and avoid confrontation of the opposite hydraulic circuits.
No takes yet. Share an insight, caveat, or question.
Sayed Nour (2020) studied Sudden cardiac arrest / Acute respiratory distress syndrome (ARDS) (n=11). Endothelial Shear Stress (ESS) enhancement via a noninvasive pulsatile device vs. Conventional CPR was evaluated on Restoration of hemodynamics and urine output. A noninvasive pulsatile device enhancing endothelial shear stress restored hemodynamics (systolic blood pressure >100 mmHg) and urine output in pediatric animal models of refractory cardiac arrest.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: