Objective. To assess the face, content, and construct validity of the Voxel-Man TempoSurg Virtual Reality simulator. Participants and Methods. 74 ear, nose, and throat (ENT) surgeons participated. They were assigned to one of two groups according to their level of expertise: the expert group (n=16) and the novice group (n=58) . The participants performed four temporal bone dissection tasks on the simulator. Performances were assessed by a global score and then compared to assess the construct validity of the simulator. Finally, the expert group assessed the face and content validity by means of a five-point Likert-type scale. Results. experienced surgeons performed better (p<.01) and faster (p<.001) than the novices. However, the groups did not differ in terms of bone volume removed (p=.11) or number of injuries (p=.37) . 93.7% of experienced surgeons stated they would recommend this simulator for anatomical learning. Most (87.5%) also thought that it could be integrated into surgical training. Conclusion. The Voxel-Man TempoSurg Virtual Reality simulator constitutes an interesting complementary tool to traditional teaching methods for training in otologic surgery.
No takes yet. Share an insight, caveat, or question.
Varoquier et al. (2017) studied this question.