A cross-flow fluidized bed paddy dryer with a capacily of 200 kgh was designed, fabricated and tested. Experimental results showed that final moisture content of paddy should not be lower than 23 % dry-basis if quality is to be maintained. Drying air temperature was keot constant at 115°C according to the recommendation of previous work. Results obtained from the mathematical model developed in this study indicatedthat optimum operating parameters should be as follows : air speed of 2.3 m/s, bed thickness of 10 cm and fraction of air recycled of 80 %. At this condition, energy consumption was close to the minimum while drying capacity was near the maximum. A prototype fluidized bed dryer with a capacity of 1 t/h was designed, fabricated and installed with the collaboration of a private company. The unit has been used for almost the whole past harvesting season in 1994 at a paddy merchant sile with preference compared to conventional column continuous dryers. More than 300 tons of paddy were dried without any problems.
No takes yet. Share an insight, caveat, or question.
Sopornonnarit et al. (1996) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: