A simple, selective and sensitive turn-on fluorescent sensor for the detection of mercury(II) ion was developed using Sybr Green I as the signal reporter and SWCNTs as the quencher. Due to the affinity of SWCNTs towards ssDNA and organic dye, Sybr Green I, thymine-rich ssDNA and SWCNTs could form a self-assembly of three components, resulting in fluorescence quenching. Upon addition of another thymine-rich ssDNA and mercury(II) ion, formation of dsDNA via T-Hg(2+)-T base pairs enabled Sybr Green I to intercalate into the dsDNA, resulting in the restoration of fluorescence. SWCNTs were found to reduce the background signal and improve the analytical sensitivity. A linear relationship between the fluorescence intensity and the concentration of mercury(II) ion was observed in the range of 20-1250 nM (R = 0.9985) with a detection limit of 7.9 nM. The proposed method was applied to detect mercury(II) ion in tap water samples with good results.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: