The dynamics of positive streamer in air under different pressure and humidity conditions was studied. The widely used three-electrode system was used to obtain the streamer propagation probability and average propagation velocity as a function of background field. A simulation was performed based on the 1.5D fluid model. Simulated intrinsic stability field for streamer propagation and corresponding average propagation velocity were in agreement with those deriving from experimental results. The intrinsic stability fields obtained with the empirical equations proposed by the author and other investigators were compared. It was analyzed that the effect of the amplitude and duration of voltage pulse applied on the needle. The statistical distribution of propagation field was explained by the dispersion of discharge time delay. The decrease of intrinsic stability field with the reduction of pressure and/or humidity was due to the increase of the conductivity of the streamer channel as a result of the weakening of attachment and/or electron-ion recombination effect.