Key result
Transcaval access with an expandable sheath enables successful TAVI without retroperitoneal bleeding.
Why the study?
Is percutaneous transcaval TAVI using an expandable sheath feasible and safe in a patient ineligible for standard access routes?
Case Report (n=1)
No
Is percutaneous transcaval TAVI using an expandable sheath feasible and safe in a patient ineligible for standard access routes?
Percutaneous transcaval venous access using an expandable sheath is a feasible and potentially safe alternative for TAVI in patients ineligible for standard access routes.
Hypothesis-generating for transcaval TAVI with expandable sheath in ineligible patients; prospective studies needed before clinical adoption.
AIMS: We aimed to describe the first percutaneous transcaval TAVI in Europe using the expandable introducer sheath (eSheath; Edwards Lifesciences, Irvine, CA, USA) for implantation of an Edwards SAPIEN 3 aortic valve (23 mm). METHODS AND RESULTS: A 72-year-old male patient presented with dyspnoea (NYHA III) in part due to severe aortic stenosis. Concomitant diseases were severe peripheral artery disease, severe chronic obstructive pulmonary disease (GOLD IV) and renal insufficiency, such that neither a transfemoral nor a transapical approach was considered favourable. An eSheath was introduced into the abdominal aorta via the femoral vein and the inferior vena cava. TAVI was then performed according to standard procedures. After TAVI, the veno-arterial junction was occluded with a 6 mm AMPLATZER Muscular VSD Occluder (St. Jude Medical, St. Paul, MN, USA) using an 8.5 Fr Agilis™ sheath (St. Jude Medical) inside the TAVI sheath. Aortography showed no retroperitoneal accumulation of contrast media. The femoral vein access site was closed using two prepositioned sutures (ProGlide; Abbott Vascular, Santa Clara, CA, USA). A CT scan the following day showed no retroperitoneal haemorrhage. CONCLUSIONS: Percutaneous transcaval venous access to the aorta may provide a new access strategy for TAVI in otherwise ineligible patients and appears safe with expandable sheath technology.
No takes yet. Share an insight, caveat, or question.
Ott et al. (2015) conducted a case report in Severe aortic stenosis (n=1). Transcaval TAVI using an expandable sheath (eSheath) was evaluated on Procedural success and safety (absence of retroperitoneal bleeding). Percutaneous transcaval venous access to the aorta using an expandable sheath for TAVI was successfully performed without retroperitoneal bleeding in a patient ineligible for traditional access routes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: