Key result
TAV-in-SAV shows similar 30-day mortality to redo-SAVR for failing surgical bioprostheses.
Why the study?
Does TAV-in-SAV improve clinical outcomes compared to redo-SAVR in patients with failing surgical aortic bioprostheses?
Observational (n=205)
Yes
Does TAV-in-SAV improve clinical outcomes compared to redo-SAVR in patients with failing surgical aortic bioprostheses?
Answers are grounded in this paper and cite their sources.
TAV-in-SAV offers a safe alternative to redo-SAVR for failing surgical aortic bioprostheses, with similar 1-year mortality and shorter hospital stays.
AIMS: Transcatheter aortic valve implantation for a failing surgical bioprosthesis (TAV-in-SAV) has become an alternative for patients at high risk for redo surgical aortic valve replacement (redo-SAVR). Comparisons between these approaches are non-existent. This study aimed to compare clinical and echocardiographic outcomes of patients undergoing TAV-in-SAV versus redo-SAVR after accounting for baseline differences by propensity score matching. METHODS AND RESULTS: Patients from seven centres in Europe and Canada who had undergone either TAV-in-SAV (n=79) or redo-SAVR (n=126) were identified. Significant independent predictors used for propensity scoring were age, NYHA functional class, number of prior cardiac surgeries, urgent procedure, pulmonary hypertension, and COPD grade. Using a calliper range of ±0.05, a total of 78 well-matched patient pairs were found. All-cause mortality was similar between groups at 30 days (6.4% redo-SAVR vs. 3.9% TAV-in-SAV; p=0.49) and one year (13.1% redo-SAVR vs. 12.3% TAV-in-SAV; p=0.80). Both groups also showed similar incidences of stroke (0% redo-SAVR vs. 1.3% TAV-in-SAV; p=1.0) and new pacemaker implantation (10.3% redo-SAVR vs. 10.3% TAV-in-SAV; p=1.0). The incidence of acute kidney injury requiring dialysis was numerically lower in the TAV-in-SAV group (11.5% redo-SAVR vs. 3.8% TAV-in-SAV; p=0.13). The TAV-in-SAV group had a significantly shorter median total hospital stay (12 days redo-SAVR vs. 9 days TAV-in-SAV; p=0.001). CONCLUSIONS: Patients with aortic bioprosthesis failure treated with either redo-SAVR or TAV-in-SAV have similar 30-day and one-year clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Spaziano et al. (2017) conducted an observational in Failing surgical aortic bioprostheses (n=205). Transcatheter aortic valve implantation for a failing surgical bioprosthesis (TAV-in-SAV) vs. Redo surgical aortic valve replacement (redo-SAVR) was evaluated on All-cause mortality at 30 days (p=0.49). TAV-in-SAV for failing surgical aortic bioprostheses resulted in similar 30-day all-cause mortality compared to redo-SAVR (3.9% vs. 6.4%; p=0.49) in a propensity-matched analysis.
Synapse has enriched 10 related papers. Consider them for comparative context: