Mechanical and electrical coupling at nanoscale metallic contacts was investigated using a conducting-probe atomic force microscope (AFM). The current-voltage responses were non-Ohmic, symmetric about zero bias, with conductance values smaller than the quantum conductance limit, which indicate electron tunneling through an insulating layer. Using a self-consistent contact mechanics model and a parabolic tunneling model for thin insulating layers, we determined the contact area, barrier height, and barrier thickness as a function of applied contact load. The results suggest the presence of two insulating layers: an oxide layer on the AFM tip and an organic contaminant layer on the metallic surface.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2008) studied this question.