By comparing the worn and untouched locations of a tungsten-carbide/carbon surface of a dry-running twin-screw rotor, we demonstrate that tungsten-oxide Raman modes become observable only at worn locations and the integral intensity of the Raman line at 680 cm−1, which is related to the incipient oxidation of the tungsten-carbide stretching mode, is enhanced. Its frequency and width moreover change significantly, thus indicating the mechanical distortion of the bonding that has been occurred during the wearing process. The shape of the tungsten-oxide Raman lines, resembling the Voigt function, hints at a surface morphology that is a characteristic for an amorphous solid environment. Our Raman scattering results may be exploited to characterize the degree of wear of coated surfaces and to identify signatures of a tribological layer.