8 specimens of beam-to-column bolted end-plate connections with various details and welded I-shaped section columns and beams were tested under monotonic loads. Based on the specification for the end-plate connection rotation proposed, the contribution of the panel zone and the gap between the end-plate and column flange to the joint rotation have been obtained. The influences of both flush and extended types, column stiffeners, end-plate rib stiffeners, bolt sizes and end-plate thicknesses etc on the joint behaviour have been compared. The test results indicate that all these connections tested are typically semi-rigid. For the flush and extended end-plate connection, the joint rotation mainly derives from the relative deformation between the end plate and the column flange and the shearing deformation of the panel zone respectively. Using a special method to measure bolt strain, the bolt tension forces and their development and distribution have been depicted and studied, and two bolt tension force distribution models for end-plate connections using pretensioned bolts are recommended.
No takes yet. Share an insight, caveat, or question.
Shi et al. (2010) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: