Key result
Subject-specific computer simulations incorporating capillary filtration accurately predict actual times to presyncope.
Why the study?
Does capillary filtration accurately model the cardiovascular response and time to syncope during orthostatic stress in a computer simulation?
Does capillary filtration accurately model the cardiovascular response and time to syncope during orthostatic stress in a computer simulation?
Subject-specific simulations demonstrate that capillary filtration is a prominent mechanism causing orthostatic intolerance, which may have clinical and spaceflight applications.
Supports capillary filtration modeling for orthostatic intolerance; leaves open clinical and spaceflight translation pending validation.
BACKGROUND: Of the many possible factors that may contribute to orthostatic intolerance, the loss of circulating blood because of capillary filtration is one of the few that can explain the gradual decline of arterial pressure during stand tests. This study used a computer model to investigate the relative importance of haemodynamic parameters, including capillary filtration, as potential contributors to orthostatic intolerance. Simulated orthostatic tolerance times were compared to previous experiments combining head-up tilt and lower body negative pressure graded orthostatic stress, which provided haemodynamic data, in particular haematocrit measurements that allowed subject-specific modelling of capillary transport. MATERIALS AND METHODS: The cardiovascular system was simulated using a seven-compartment model with measured heart rate, stroke volume, total peripheral resistance, mean arterial pressure and haematocrit data for 12 subjects. Simulations were controlled by decreasing the total blood volume at the measured rates of capillary filtration until cerebral pressure dropped below a threshold for consciousness. Predicted times to syncope were compared to actual times to presyncope, and sensitivity of arterial pressure and cardiac output to independent system parameters were determined. RESULTS: There was no statistical difference in modelled times to syncope and actual times to presyncope. Both arterial pressure and cardiac output were most sensitive to total blood volume and least sensitive to caudal compliance parameters. CONCLUSIONS: The feasibility of subject-specific simulations of cardiovascular response to orthostatic stress was demonstrated, providing stronger evidence that capillary filtration is a prominent mechanism in causing orthostatic intolerance. These results may have clinical and spaceflight applications.
No takes yet. Share an insight, caveat, or question.
Etter et al. (2011) studied Orthostatic intolerance (n=12). Subject-specific computer modelling of capillary filtration vs. Actual experimental data was evaluated on Time to syncope. Subject-specific computer simulations incorporating capillary filtration predicted times to syncope that were not statistically different from actual times to presyncope.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: