Answers are grounded in this paper and cite their sources.
It is known that a reduction of the field-of-view in 3-D X-ray imaging is proportional to a reduction in radiation dose. The resulting truncation, however, is incompatible with conventional reconstruction algorithms. Recently, a novel method for region of interest reconstruction that uses neither prior knowledge nor extrapolation has been published, named approximated truncation robust algorithm for computed tomography (ATRACT). It is based on a decomposition of the standard ramp filter into a 2-D Laplace filtering and a 2-D Radon-based residual filtering step. In this paper, we present two variants of the original ATRACT. One is based on expressing the residual filter as an efficient 2-D convolution with an analytically derived kernel. The second variant is to apply ATRACT in 1-D to further reduce computational complexity. The proposed algorithms were evaluated by using a reconstruction benchmark, as well as two clinical data sets. The results are encouraging since the proposed algorithms achieve a speed-up factor of up to 245 compared to the 2-D Radon-based ATRACT. Reconstructions of high accuracy are obtained, e.g., even real-data reconstruction in the presence of severe truncation achieve a relative root mean square error of as little as 0.92% with respect to nontruncated data.
No takes yet. Share an insight, caveat, or question.
Xia et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: