Key result
e-PTFE artificial chordae for anterior mitral repair linked to ~96% absent or trivial regurgitation at discharge.
Why the study?
Does the use of expanded polytetrafluorethylene (e-PTFE) artificial chordae improve clinical and echocardiographic outcomes in patients with anterior mitral leaflet pathology?
Observational (n=122)
Does the use of expanded polytetrafluorethylene (e-PTFE) artificial chordae improve clinical and echocardiographic outcomes in patients with anterior mitral leaflet pathology?
The use of e-PTFE artificial chordae for anterior mitral leaflet repair is a safe procedure that yields excellent long-term clinical and echocardiographic outcomes.
Supports e-PTFE chordae in anterior mitral repair; leaves open randomized confirmation of durability.
This report describes the authors' clinical experience with expanded polytetrafluorethylene (e-PTFE) sutures to replace the anterior mitral leaflet chordae for valve repair. Between November 1986 and July 1995, 203 patients underwent operations with e-PTFE chordae insertion. Among these, 122 had artificial chordae utilized for anterior mitral leaflet repair. Four patients had the valve replaced during the same operation because of an unsatisfactory result. One patient died from respiratory insufficiency 16 days after operation. Transoesophageal echocardiography at discharge from hospital showed no evidence of regurgitation in 81 cases, and trivial regurgitation in 36. During a mean follow-up of 36.6 (range 1-106) months two other patients died from causes unrelated to the valve repair, while one patient had a transient ischaemic attack returning to sinus rhythm. Two patients were reoperated on 12 and 18 months respectively after their initial operation for progression of valvular degeneration causing natural chordae rupture. Among the remaining 113 patients, 111 are in New York Heart Association functional class I and yearly transoesophageal echocardiography has shown absent or trivial regurgitation. The utilization of e-PTFE as artificial chordae for anterior mitral leaflet pathology is a safe and reliable procedure, yielding excellent results and increasing the number of candidates for valve repair.
No takes yet. Share an insight, caveat, or question.
Claudio Zussa (1997) conducted an observational in Anterior mitral leaflet pathology (n=122). e-PTFE artificial chordae was evaluated. Use of e-PTFE artificial chordae for anterior mitral leaflet repair resulted in absent or trivial regurgitation in 117 of 122 patients at discharge, with 111 in NYHA class I at 36.6 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: