An improved technique for incorporating saturation into the q-d axis model (Park's model) of a synchronous machine is proposed. By choosing magnetizing flux linkage as a state variable, iterative procedures required by traditional methods are avoided. The saturation function is represented by an arctangent function which has some distinct advantages over polynomial representations and look-up tables. In particular, the parameters of the proposed function all have physical significance and the proposed function is defined over an infinite range of flux linkage. The model is verified for steady-state and transient conditions using a laboratory synchronous machine-rectifier system similar to those commonly used for naval and aerospace power generation.
No takes yet. Share an insight, caveat, or question.
Corzine et al. (1998) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: