The behavior of base-isolated building frame is investigated with the help of a numerical study for far-field and near-field earthquakes with directivity and fling-step effects. Both design-level and extreme-level earthquakes are considered. Selected response parameters are peak floor displacement, acceleration, base shear, and isolator displacement. Inelastic behavior of base-isolated structure during the earthquake is investigated performing nonlinear time history analysis of a ten-story building frame. This study shows that base isolation is not effective for near-field earthquakes. Even for design-level earthquake, the frame gets significantly into inelastic range for earthquakes with fling-step effect.