The Z-source dc circuit breaker has been introduced as a new circuit for quickly and automatically switching off in response to faults. A modified Z-source breaker design is introduced for the operation at medium-voltage dc with future applications in naval ship power systems. Compared to existing designs, the respective design will allow for greater control of step changes in load. This new design also limits capacitor current in the circuit and can be easily modified for fault detection. Analysis of the breaker operation is presented during both the fault and step changes in load. Low-voltage laboratory validation of the breaker was carried out on two different versions of the proposed circuit.
No takes yet. Share an insight, caveat, or question.
Maqsood et al. (2015) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: