We report an unusual case of vasospasm of a grafted radial artery complicated with ventricular fibrillation during the postoperative course of coronary artery bypass graft surgery. To our knowledge this is the first documented case of a radial artery graft spasm leading to a severe arrhythmia. The arrhythmia resolved spontaneously. Radial artery graft spasm was demonstrated by angiography and was successfully resolved by intravenous nitroglycerin administration.
No takes yet. Share an insight, caveat, or question.
Gabe et al. (2001) studied this question.