We have designed and fabricated test structures that allow the determination of the critical current density and processing run-out of low T/sub c/ Josephson junctions based only on room-temperature measurements. We demonstrated that the 300 K tunneling conductance of a junction barrier is proportional to the critical current at 4.2 K. This testing technique greatly reduced the time required to characterize a process wafer. In one demonstration we tested hundreds of devices across a 150-mm-diameter wafer in less than an hour. In another we used a selective niobium anodization process with only two mask levels to determine the critical current density of a Nb/AlO/sub x//Nb trilayer within a day of its deposition. We have also used automated probing stations to decrease testing delays further and thus to improve process cycle time.
No takes yet. Share an insight, caveat, or question.
Berggren et al. (1999) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: