The occurrence of significant co-extraction of buffer anions by the ion exchanger Aliquat 336 is unavoidable when high levels of system buffering is required. The co-extraction will result in inaccurate equilibrium and mass-transfer characterization of such a system unless its occurrence is taken into account, making process design and control difficult. A study of the equilibrium of phenylalanine extraction using Aliquat 336, a system where high levels of hydroxyl co-extraction occurs, was used as a model case to develop a method of accounting for co-extraction in mass-transfer modeling. Analysis of the equilibrium between bulk-aqueous-phase chloride and phenylalanine concentrations during mass transfer in a stirred-transfer cell showed there to be linear equilibrium relationships between the two parameters for a given extraction system of the form C(Cl,t) = alpha(C(A,t) - C(A,0)) for forward extraction and C(Cl,t) = epsilon C(A,t) + C(Cl,0) for backward extraction. The constants of proportionality of these relationships, or the "co-extraction constants," alpha and epsilon, were shown to be related to the selectivity of Aliquat 336 for the phenylalanine anion by the relationships alpha = -(1/S + 1) and epsilon; = -(1/S(-1) + 1). The linear equilibrium relationships were used to develop two-film theory mass-transfer models for both forward and backward extraction that account for co-extraction. These showed much higher accuracy in modeling stirred-transfer-cell data than the equivalent models which ignored co-extraction.
No takes yet. Share an insight, caveat, or question.
Scarpello et al. (2000) studied this question.