Key result
3D volumetric CT detects ~10% greater posterior humeral head subluxation than 2D CT.
Why the study?
It was unknown whether the percentage of posterior humeral head subluxation measured on axillary radiographs is consistent with measurements on 2D axial or 3D volumetric CT in Walch type B glenohumeral osteoarthritis.
Does the measurement of posterior humeral head subluxation vary across imaging modalities (radiographs, 2D CT, and 3D CT) in patients with Walch type B shoulders?
Cross-Sectional (n=30)
Does the measurement of posterior humeral head subluxation vary across imaging modalities (radiographs, 2D CT, and 3D CT) in patients with Walch type B shoulders?
Posterior humeral head subluxation values vary significantly between 2D and 3D CT measurement techniques, primarily due to linear versus volumetric differences.
Answers are grounded in this paper and cite their sources.
2D CT underestimates subluxation versus 3D in Walch B shoulders; leaves open standardized volumetric thresholds for research and planning.
Background The Walch type B pattern of glenohumeral osteoarthritis is characterized by posterior humeral head subluxation (PHHS). At present, it is unknown whether the percentage of subluxation measured on axillary radiographs is consistent with measurements on 2-dimensional (2D) axial or 3-dimensional (3D) volumetric computed tomography (CT). The purpose of this study was to evaluate PHHS across imaging modalities (radiographs, 2D CT, and 3D CT). Methods A cohort of 30 patients with Walch type B shoulders underwent radiography and standardized CT scans. The cohort comprised 10 type B1, 10 type B2, and 10 type B3 glenoids. PHHS was measured using the scapulohumeral subluxation method on axillary radiographs and 2D CT. On 3D CT, PHHS was measured volumetrically. PHHS was statistically compared between imaging modalities, with P ≤ .05 considered significant. Results The mean PHHS value for the entire group was 69% ± 24% on radiographs, 65% ± 23% with 2D CT, and 74% ± 24% with 3D volumetric CT. PHHS as measured on complete axillary radiographs was not significantly different than that measured on 2D CT ( P = .941). Additionally, PHHS on 3D volumetric CT was 9.5% greater than that on 2D CT ( P < .001). There were no significant differences in PHHS between the type B1, B2, and B3 groups with 2D or 3D CT measurement techniques ( P > .102). Conclusion Significant differences in PHHS were found between measurement techniques ( P < .035). A 9.5% difference in PHHS between 2D and 3D CT can be mostly accounted for by the linear (2D) vs. volumetric (3D) measurement techniques (a linear 80% PHHS value is mathematically equivalent to a volumetric PHHS value of 89.6%). Surgeons should be aware that subluxation values and therefore thresholds vary across different imaging modalities and measurement techniques.
No takes yet. Share an insight, caveat, or question.
Matache et al. (2020) conducted a cross-sectional in Walch type B pattern of glenohumeral osteoarthritis (n=30). 3D volumetric CT vs. 2D CT was evaluated on Posterior humeral head subluxation (PHHS) (MD 9.5, p=<.001). Posterior humeral head subluxation measured on 3D volumetric CT was 9.5% greater than when measured on 2D CT (74% vs 65%, P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: