Answers are grounded in this paper and cite their sources.
Laparoscopic surgery carried out under general anaesthesia is associated with physiological changes, which also determine changes in intra-ocular pressure. We measured intra-ocular pressure at each phase of gynaecological laparoscopy, carried out under propofol-alfentanil-isoflurane general anaesthesia, in young women of ASA 1 status, with no pre-existing eye disease. Measurements were made with a Perkins applanation tonometer. Mean arterial pressure and end-tidal CO2 tension were kept constant throughout the study. Intra-ocular pressure decreased significantly after induction of anaesthesia, remained unchanged after a pneumoperitoneum of up to an intraperitoneal pressure of 15 mmHg had been created, increased significantly with head down tilt, but did not increase significantly above pre-induction values. Adequate depth of anaesthesia compensated for the intra-ocular pressure increase caused by head down position. Plateau airway pressure, considered as reflecting intrathoracic pressure, increased with intraperitoneal pressure elevation. However, such changes did not correlate with intra-ocular pressure changes.
No takes yet. Share an insight, caveat, or question.
Lentschener et al. (1996) studied this question.